Data Ingestion Recommendations
- The following recommendations are intended to improve ingestion performance and reliability:
- Implement retry logic with exponential backoff when receiving HTTP 429 (rate limiting) or 5xx (server) responses.
- Refresh Auth0 tokens prior to expiration rather than waiting for a 401 Unauthorized response.
- Batch multiple records into a single request where practical to reduce network overhead and improve throughput.
- Maintain consistent payload sizes. Smaller, more frequent payloads generally provide better ingestion performance and reduce the likelihood of endpoint rate limiting.
- Recommended payload size: 5–30 KB
- Recommended sustained send rate: less than 100 KB/s
- Select the ingestion format appropriate for the data structure:
- Column Format: Recommended for tabular and time-series data
- Record Format: Recommended for key-value and event-based data
Data Recording Requirements
The following requirements must be met for successful ingestion and analytics processing:
- For a given Part ID (Serial Number), Component ID, Sensor, and Timestamp combination, only one measurement value may exist.
- Note: Component IDs are used to associate subcomponent data with parent assembly data within LinePulse.
- Column names, metric names, and identifiers must:
- Use alphanumeric characters and underscores only
- Contain no spaces or special characters
- Be descriptive and consistently applied across the production environment
- The following fields are required for all production records:
- Part ID
- Model Number
- Timestamp (UTC format) representing when the measurement was taken
- Location > Line, indicating which production line the data belongs to
- Location > Station, indicating which production station the data belongs to
Unsupported Data Patterns
The following data patterns are not supported and may result in data rejection, inaccurate analytics, or implementation delays:
- Reusing the same Part ID across multiple physical parts within different plants or production lines.
- Changing the model number associated with a Part ID during production.
- Example: Serial Number 123456 is reported as Model A at Station 10 and Model C at Station 50.
- Sending data at a sustained rate exceeding 100 KB/s or individual payloads exceeding 1 MB without prior approval.
- Storing plant, line, station, or location information in sensor values rather than designated location fields.
- Sending duplicate records containing identical values.
- Overwriting previously submitted records instead of creating new records to reflect changes, updates, or corrections.
- Using temporary or placeholder values that are intended to be overwritten later.
- Using sensor or measurement fields to store metadata such as plant, line, station, process, or operation identifiers.
- Using timestamps that do not represent the actual measurement time.
- Example: Recording the ingestion time rather than the time the measurement was captured.
- Configurations exceeding 50,000 sensors on a single production line without prior review.
Items Requiring Advance Notification to Acerta
Acerta must be notified prior to implementation if any of the following conditions apply:
- Part IDs are unique only within a plant or production line and are not globally unique across the enterprise.
- Failure modes, fault codes, or diagnostic information are stored as measurement signals rather than discrete event records.
- Source systems are unable to detect, prevent, or monitor duplicate records during data collection or transmission.
- Expected ingestion rates, payload sizes, or sensor counts exceed the outlined recommended limits.