Signal Management

Configuring Signal Data: Signal Management​

Stations, signals, and part attributes can be configured using the Signal Management module. They can be configured individually or by selecting multiple entities and applying the same properties to all at once. Properties that can be configured include Friendly Name, Entity Type, and more.

To select one or more signals for editing​

  1. (If required) Select a Plant.

  2. From the Navigation menu, click System Settings.

    The Settings menu appears.

  3. Click Data Management → Signal Management.

    The Signal Management screen appears.

  4. tip

    To display friendly names in the query tree, select Use Friendly Names, if available.

  5. (Optional) Select a Line.

  6. (Optional) Use the search box to locate specific signals.

  7. tip

    To reset the search parameters, click CLEAR SELECTION.

  8. (Optional) Click Filter Icon to restrict which signals appear in the query tree.

    See Working with Query Filters for more information.

  9. Select a signal.

    LinePulse displays details for the selected entity.

  10. (As required) Select additional signals.

    LinePulse displays details for the selected entities.

tip

To select a block of adjacent signals, select the first signal, then press SHIFT and select the final signal. LinePulse selects all signals between these two signals. Use CTRL to add or remove a single entry.

Multi-Select Demonstration
note

When multiple entities are selected, LinePulse displays properties that are common to all of the selected entities. Only properties common to all can be updated.

tip

To reset the currently selected signals, click CLEAR SELECTION.

To view a selection summary for your selected signals​

  1. Select one or more signals.

  2. Click SEE SELECTION SUMMARY (#).

  3. note

    (#) indicates the total number of signals that are currently selected.

    The Summary of Selected Measurements dialog box appears.

    tip

    To display friendly names in the Summary of Selected Measurements dialog box, select Use Friendly Names.

  4. Click CLOSE when you are ready to return to the Signal Management screen.

To enable/disable one or more signals​

  1. Select one or more signals.

  2. Click the Signal Active dropdown menu.

  3. Select either Enabled or Disabled.

    LinePulse updates the selected signals.

note

Disabled signals will still appear in the Signal Management tree, but will no longer appear in any query builders.

To add or edit a friendly name​

note

The procedure to create a new Friendly Name or edit an existing one is identical.

  1. Select a signal.

    Only one signal can be edited at a time

  2. To the right of the Friendly Name field, click configure.

    LinePulse switches the Friendly Name field to edit mode.

  3. Enter a new Friendly Name or edit the existing one.

  4. Click SAVE.

    LinePulse saves your changes.

To remove a friendly name​

  1. Select a signal.

    Only one signal can be edited at a time

  2. To the right of the Friendly Name field, click EDIT.

    LinePulse switches the Friendly Name field to edit mode.

  3. Delete all text in the Friendly Name field.

  4. Click SAVE.

    LinePulse removes the selected friendly name.

To configure one or more signal entity types​

  1. Select one or more signals.

  2. Open the Entity Type dropdown menu.

    The options below appear.

  3. Entity Types
  4. Select the type you wish to set.

    The Entity Type Change Summary dialog box appears. Read it carefully to confirm what changes will be made.

  5. Click CHANGE ENTITY TYPE.

    LinePulse saves your changes.

To configure signal associations​

You can associate signals with other signals to form relationships between them. A signal can be designated as either a: Measurement, Upper Limit, Lower Limit or Result.

  1. Select one or more signals.

  2. To the right of the Associations section, click CONFIGURE.

    The Associations panel appears.

    Each of your selected signals appears in one of four categories, according to its current association value. The default association value is Measurement.

  3. Click and drag each signal into the desired category.

  4. tip

    Click the X next to a signal to deselect it and remove it from the associations panel.

    note

    As you drag a signal over each box, LinePulse will highlight it in either green or red to indicate whether or not the signal can be associated with that value.

    In general, multiple Measurement values are permitted, but only one value is permitted for each of the other three categories.

    The Measurement box cannot be left empty and will appear highlighted in red if all signals are removed. The CONFIRM button will also be disabled, preventing you from proceeding.

  5. Once you have made all of your desired changes, click CONFIRM.

    The Association Changes dialog box appears.

    LinePulse outlines all of the changes you wish to make. Review them carefully to ensure that everything is correct.

  6. tip

    Click any entry to view more information regarding how it will be converted.

  7. Click NEXT.

    The Association Changes summary page appears.

  8. Click I UNDERSTAND. SAVE THIS CONFIGURATION.

    LinePulse saves your changes.

To add/edit Quality Characteristics tags​

Quality Characteristics are tags that, once applied to a signal, will appear beside that signal throughout LinePulse. These are particularly useful when filtering query builders to restrict a treeview to display only those signals with the same tag applied to them.

  1. Select one or more signals.

  2. note

    Only signals with an Entity Type of 'Measurement' can have Quality Characteristics tags.

  3. Select a Quality Characteristics value.

    LinePulse applies the selected Quality Characteristics tag to your selected signals and saves your changes.

To edit result classification values​

Use the Result Classifications section to configure signal result classifications.

note

Only signals with an Entity Type of 'Result' can be configured.

  1. Select one or more signals.

  2. To the right of the Result Classifications section, click VIEW.

    The Classifications panel appears, displaying previously configured values.

  3. Select the classification values you wish to edit.

  4. Click EDIT.

  5. Select a new Category for one of the selected classification values.

    LinePulse updates each of the selected classification values with this new Category.

  6. (Optional) Select Apply configuration to the entire station(s) if you wish to apply these edits to each Result in the station.

  7. Click SAVE.

    LinePulse saves your changes.

To configure final station​

Configure Final Station Demonstration
  1. Hover over the station you wish to set to final station.

    The CONFIGURE STATION button appears.

  2. Keeping your cursor inside the grey box, click CONFIGURE STATION.

    If you leave the grey box, the button will go away.
    The Station Details panel is displayed.

  3. Toggle the final station on or off.

To set signal distribution​

  1. Click on the signal you wish to edit.

    This is only available for signals with the Measurement entity type.

  2. Turn Single Sided on.

    Activates the distribution options.

  3. Select Lower Boundary or Upper Boundary.

    LinePulse saves your changes.

To add or edit result classification values​

Configure Final Station Demonstration
  1. Select one or more signals.

  2. note

    This is only available for signals with the Result entity type.

  3. To the right of the Result Classifications section, click CONFIGURE.

    The Edit Result Classifications panel appears.

  4. Click Add Classification to add a new value.

  5. Select a new category from the Result column.

  6. (Optional) Enter a Failure Mode.

  7. Click SAVE CHANGES.

To use Signal Agent​

Signal Agent is an AI assistant that uses a large language model (LLM) to understand requests written in everyday language. It reviews the signal settings on the selected line and explains why it recommends each change. Customer Administrators and Contributors can use Signal Agent to ask about signals on a production line, request a specific change, or get a configuration plan.

  1. On the Signal Management page, click the sparkle icon (Ask Signal Agent) in the lower-right corner.

  2. Check the Plant at the top of the chat and select the Line whose signals you want to work with.

  3. Ask a question or describe what you want to change. You can use one of the suggested prompts below.

  4. If you request a plan, review the suggested entity types and associations. For each signal, the agent explains why it suggests a change, such as linking a measurement to its upper limit.

  5. When the agent lists changes for confirmation, click Confirm to apply them or Reject to discard them. To apply only part of a plan, reject the full list, ask for just the changes you want, and confirm the revised list.

  6. After you confirm, the agent reports how many changes succeeded, failed, or were skipped.

tip

Suggested prompts​

Use station and signal names from your line in place of Final Assembly and Torque Max.

Get to know Signal Agent

  • What can you help me do with my signals?
  • What can’t you do?

Count and explore signals

  • How many signals are on this line, and how many are there of each entity type?
  • How many signals are at the Final Assembly station? Break them down by entity type.

Review or change the configuration

  • Analyze Final Assembly and suggest entity types and associations for its signals.
  • Review the entity types on Final Assembly.
  • I want to update the entity types for all measurements at Final Assembly. What changes do you suggest?
  • Change the entity type of Torque Max to Upper Limit.
  • On this line, signal names containing “max” indicate an upper limit, and names containing “min” indicate a lower limit.