Quality Dashboard
About the Quality Dashboard Module
The Quality Dashboard module allows you to create and view run charts in a custom-designed format, updated in a user-configurable time frame. You can also use it to view Key Performance Indicators (KPIs) that reflect the same user-defined parameters. Create as many customized dashboards as you need and easily recall them, or dashboards created by other LinePulse users at your plant.
You can view Query Details for the currently active dashboard query at the bottom of the screen.
Understanding KPIs
Key Performance Indicators (KPIs) are an integral part of the Quality Dashboard module. These are measurable values that indicate how effectively your plant is achieving specific manufacturing quality objectives.
KPIs are essential in decision-making because they provide actionable insights, allowing for performance evaluation over time. By regularly monitoring KPIs, you can make informed decisions, adjust strategies and achieve continuous improvement.
LinePulse provides the following KPIs:
| KPI | Formula |
|---|---|
| SN'S PROCESSED | The number of processed serial numbers within the specified time period |
| SN'S COMPLETED | The number of completed serial numbers within the specified time period |
| FTT | (The number of first time through serial numbers / The number of processed serial numbers) x 100 |
| YIELD | (The number of completed serial numbers / The number of processed serial numbers) x 100 |
| LAST PART | The date and time of the last processed serial number within the line respecting the filters for the dashboard within the "KPI Period" |
Here are the definitions for some of the terms used above:
Processed
When a serial number goes through at least one final station, it is considered processed. How the system determine it went through a final station is by checking if the serial number has a signal record from any of the final stations of the line.
Completed
When a serial number has results in at least one of the final stations, if the final station with latest results has all results passed, the serial number is considered completed.
First Time Through
- A serial number is considered First Time Through if it is a Completed Part and all of the following additional conditions are met:
- All results in all final stations are passed (disabled result signals excluded) - not just the final station with the latest results
- Doesn't have multiple occurrences of the same signal (in any station) except for signals that are global part attribute signals, component signals, or disabled signals
Understanding Failure Pareto Charts
What is a reject (failure)
When a serial number receives a failure result at any station, it is considered a reject. A serial number can have multiple rejections if it receives multiple failure results at different timestamps.
The Rejects tab in the Quality Dashboard includes a Failure Pareto Chart that visualizes failure data across the entire line. It ranks failure modes by frequency, making it easy to identify which failures occur most often and where to focus improvement efforts.
The Failure Pareto Chart supports both Live and Historical modes, consistent with the rest of the Quality Dashboard:
- Live Mode uses the configured Live Data Period to display up-to-date failure data.
- Historical Mode allows you to view failure data for a specific time range.
Example scenarios:
-
A serial number fails in station A for reason A, and fails in station B for reason B, this would be two rejections, 1 at each station.
-
A serial number fails at a station for reasons A and B. Here is how the rejection count would change based on different scenarios.
- If both failures occur at the same time: Rejection Count = 1
- If failures occur at 2 different times:
- If "Operation Count" is ALL: Rejection Count = 2
- If "Operation Count" is either FIRST or LAST: Rejection Count = 1
Using the Quality Dashboard Module
To create a new dashboard
From the Navigation menu, click .
LinePulse displays the Quality Dashboard main screen.
If no dashboards have previously been created for the current line, LinePulse will display the following message; otherwise, the
CREATE DASHBOARDbutton will appear at the top-right of the Quality Dashboard screen. Clicking either one will have the same effect:Click
CREATE DASHBOARDLinePulse displays the Quality Dashboard Builder, starting with the Details page.
Select a Line.
Dashboards can only display run charts for a single line.
Enter a Dashboard Name.
The Dashboard Name must be unique.
Click
NEXTLinePulse displays the Quality Dashboard Builder → Signals page.
Select one or more signals.
Selected signals will appear on the right side of the screen.
Click
NEXTLinePulse displays the Quality Dashboard Builder → Filters page.
Select a Live Data Period
(Optional) Enter the Max Chart Data Points.
or enter the Last X Parts to use other mode
(Optional) Select any Model Numbers you wish to include.
(Optional) Select a Result you wish to include.
To configure Results in Signal Management, click Configure Now.
(Optional) Enter serial numbers of parts you wish to exclude.
(Optional) Click
ADD PART ATTRIBUTEto include specific Part Attributes.Click
NEXT.LinePulse displays your new dashboard.
If you expect previously created dashboards to appear, but none are visible, make sure that you have selected the correct line at the top of the LinePulse screen.
You can also create a new dashboard by clicking CREATE DASHBOARD from the Change Dashboard screen (see below).

You can select a maximum of 64 signals.
To make selecting them easier, you can restrict the signals that LinePulse will display on this screen by either: 1) entering a partial search term, or 2) clicking
(Filter Signals), which displays a pop-up menu.
To switch dashboards
From the Navigation menu, click .
LinePulse displays the Quality Dashboard main screen.
If no dashboards are available for the current line, LinePulse will display the following message. You will not be able to switch dashboards until more are created.
Click the title of the currently selected dashboard.
LinePulse displays recently opened dashboards.
Select a dashboard from this list, or click
View All Dashboardsto view any dashboards that do not appear in the Recent Dashboards menu.If you have selected a dashboard, LinePulse will open it now; otherwise, LinePulse displays a list of all dashboards configured for this and other lines. Continue to the next step.
Select a dashboard.
Click
Open DashboardLinePulse opens the selected dashboard.

Enter a search term to narrow down the list of dashboards. This will make it easier to select a single dashboard from a long list.
To change a dashboard's display options
From the Navigation menu, click .
LinePulse displays the Quality Dashboard main screen.
Select or create a Quality Dashboard.
Click
Display OptionsThe Customize Display dialog box appears.
Select a Dashboard View.
LinePulse updates the number of charts displayed on your dashboard.
(Optional) Select a Chart Warning Type.
(Optional) Enter a Warning Value and Critical Value.
(Optional) Select an x-axis option (Time or Records) to change the chart's x-axis.
LinePulse updates your dashboard as you make a selection.
(Optional) Select any Chart Overlays that you wish to include with your dashboard's charts.
(Optional) Set Page Autocycle.
If left disabled, LinePulse will not refresh your dashboard after it has been loaded.
(Optional) Adjust the FTT Critical and FTT Warning values.
(Optional) Adjust the Yield Critical and Yield Warning values.
Click
Xor click anywhere outside of the Customize Display dialog box to close it.

Updates occur in real time as you make your selection.
If any signals fall between the Warning Value and the Critical Value, the chart will appear outlined in yellow; if any signals exceed the Critical Value, the chart will appear outlined in red. When you hover your mouse cursor over one of these charts, it will appear with a corresponding yellow or red background.
To edit a dashboard
From the Navigation menu, click .
LinePulse displays the Quality Dashboard main screen.
Select the dashboard you wish to edit.
See To switch dashboards for more information.
Open the
⋮menu.Select
Edit Dashboard.LinePulse opens your dashboard for editing in the Edit Quality Dashboard screen.
Make any required changes.
See To create a new dashboard for more information.
To delete a dashboard
From the Navigation menu, click .
LinePulse displays the Quality Dashboard main screen.
Select the dashboard you wish to delete.
See To switch dashboards for more information.
Open the
⋮menu.Select
Delete Dashboard.A confirmation dialog box appears.
Click
DELETE.LinePulse deletes your dashboard.
To view a chart's study statistics
From the Navigation menu, click .
LinePulse displays the Quality Dashboard main screen.
Select a dashboard.
LinePulse displays the selected dashboard.
Click on the chart you wish to view.
LinePulse displays the chart in the Study Statistics popup screen.
(Optional) Click
OPEN ANALYTICSto view the results in Capability Metrics.The result opens in a new browser tab.
To view the Failure Pareto Chart
From the Navigation menu, click .
LinePulse displays the Quality Dashboard main screen.
Select or create a Quality Dashboard.
See To switch dashboards or To create a new dashboard for more information.
Click the Rejects tab.
LinePulse displays the Failure Pareto Chart for the entire line, ranked by failure frequency.
(Optional) Hover over a bar in the chart to view a breakdown of failure modes and their counts for that station.
(Optional) Switch between Live and Historical modes to view real-time or past failure data.
See To select a dashboard mode for more information.
To select a dashboard mode
Dashboards can be viewed in Live or Historical mode, depending on whether you want real-time or past data. By default, dashboards open in Live mode.
Historical mode is disabled when Last X Parts is selected, because this view always shows the latest parts and is based on part count rather than time.
Run charts use the following record limits per chart:
- Historical mode: up to 20,000 records within the selected Start and End times.
- Live mode: up to 10,000 records within the configured Live Data Period.
- Last X Parts: uses the configured part count.
If a run chart exceeds its record limit, select a shorter time range or narrow the filters to generate the chart.
Click the dropdown menu at the top left beside the dashboard name.
Select a mode:
Choose
Liveto view real-time data as it updates.Choose
Historicalto view data for a specific time range.If
Historicalis selected, click the calendar icons to choose the Start and End times.Click
UPDATE.

Troubleshooting Quality Dashboard Metrics
When KPI dashboards are not populated, this can happen for several reasons:
- No part was worked on a final station for the time period. In Live mode, the time period is from now minus the dashboard's configured time period. In Historical mode, it is the selected historical period.
- There was no data ingested for the line for the time period the dashboard is configured for. You can verify this by going to
Settings>Line Managementand checking theLast Data Receivedtime. - Filters might be configured that omit parts. Filters that contribute to KPI metrics are
Live Data Period,Model Numbers,Excluded Parts, andPart Attributes. Check whether any of these are filtering parts out.
If the FTT metric is shown as 0, it can be for several reasons:
- SNs completed are 0. To verify this, run a Part History query for a processed part, meaning a part that went through a final station, within the time window and check the result signal values.
- Parts that were completed at some point have at least one failed result. To verify this, run a Part History query for a completed part within the time window and check the result signal values.
- Parts that were completed have at least one rework record, meaning multiple readings for the same signal over time. To verify this, run a Part History query for a completed part within the time window and check for reappearing signals.
When the Quality Dashboard metrics have different values, here are several reasons:
It is normal to see different values for different KPI metrics.
For example, if 10 SNs were processed but only 3 are completed, that means 7 parts have still not completed their work in the final station.
A part is considered completed when the latest results on a final station show pass for all results. If there is no result for a certain part, that part is still considered incomplete.
To verify the data, run a Part History query for a processed part, meaning a part that went through a final station, within the time window and check the result signal values.
Dashboards in Historical view do not refresh. Dashboards in Live view refresh every 1 minute. KPI metrics get the latest data on every refresh.
If the user is in the Run charts tab, run charts fetch the latest CAP data.
If the user is in the Rejects tab, it will not fetch the latest rejects data.