Alerts | Overview
About the Alert Overview Module
The Overview module provides continuously updating data on multiple signals simultaneously. You can use this module to view real-time alerts in any line.
To learn more about the Overview module, launch the corresponding tour from the Guided Tours menu in the LinePulse Resource Center.
Using the Alert Overview Module
To change the line
From the Navigation menu, click .
LinePulse displays the Alert Overview module.
Select a line from the top left menu.
LinePulse updates the Signal/Group table to match your selection.
To select a signal/group
See Working with Tables for tips on sorting, filtering, and resizing LinePulse tables.
From the Navigation menu, click .
LinePulse displays the Alert Overview module.
Select a signal/group from the Signal/Group table.
LinePulse displays the selected signal/group in the Detailed View section.
Alternatively, select one of the small graphs, which correspond to the signals/groups currently displayed in the Signal/Group table.
To view further information about a specific data point in the Detailed View, hover your mouse cursor over that data point.
To open a signal/group in a new tab
In the large Detail View graph, click
Details.LinePulse opens the selected signal/group in the appropriate module in a new browser tab.
Troubleshooting Monitor Visibility on the Overview Page
A newly configured SVD, MVD, or Quality monitor may not appear on the Overview page immediately.
First, confirm whether the monitor was deployed upon creation.
During SVD, MVD, or Quality monitor creation, there is a Deploy upon creation option. If this was not enabled, the monitor may have been created but not deployed yet.
You can also check the monitor status here:
- Go to
System Settings. - Open
Anomaly Monitorsand then theSingle Variate,Multi Variate, orQuality Monitorstab. - Select the relevant line if needed.
- Confirm the monitor is active.
If the monitor is deployed and active, it will appear on the Overview page once it generates an alert.
If Deploy upon creation was enabled, the next thing to check is whether the monitor is active.
Go to System Settings > Anomaly Monitors > Single Variate and confirm the Active toggle is enabled for that SVD, MVD, or Quality monitor.
If it is active, the monitor is ready to run, but it still may not show on the Overview page until it produces an alert.
If the SVD, MVD, or Quality monitor is both deployed and active, it will show on the Overview page once it is alerted.
The monitor first needs to detect a breach. For SVD and MVD monitors, LinePulse automatically classifies the anomaly score, and a breach occurs when that severity meets or exceeds the configured Low, Medium, or High alert threshold. The score must strictly exceed the applicable numerical boundary to enter a severity level. See SVD anomaly severity and MVD anomaly severity for the matrices and examples. Quality monitors use a separate failure-rate alert calculation. If the alert rule is also satisfied, the monitor will generate an alert.
Once that happens, a record will be created and shown on the Overview page.
You can also review related records in the Monitors & Alerts section, including Alert History and Breach History.
If an SVD, MVD, or Quality monitor appeared on the Overview page yesterday but is gone today, the most likely reason is that the alert record expired based on the line's Alert Displayed setting.
The Overview page shows alert records for a limited number of days. This is controlled by Line Management > three-dot menu > Alert Displayed (days).
For example, if Alert Displayed is set to 1 day, an alert shown yesterday may no longer appear today.
Another thing to check is whether the monitor still exists:
- Go to
System Settings. - Open
Anomaly Monitorsand then theSingle Variate,Multi Variate, orQuality Monitorstab. - Confirm whether the SVD, MVD, or Quality monitor still exists.
If the monitor was deleted, the old alert record may still remain on the Overview page temporarily, but it will eventually expire based on the Alert Displayed setting.