Root Cause Analysis
About Root Cause Analysis (RCA)
RCA uses AI and machine learning to analyze manufacturing data and identify which signals contribute most to a specific outcome.
RCA data may be delayed by at least 12 hours compared with the real-time data used by CAP and other LinePulse modules.
In LinePulse, there are two types of RCA reports:
Investigate
The Investigate RCA report helps you understand which features are most strongly linked to a specific target. It shows you how different signals impact the outcome, making it easier to spot patterns or root causes. Use this section to get an overview of your situation.
Optimize
The Optimize RCA report lets you experiment with the values of different signals to see how those changes affect the prediction. You can adjust signal values and instantly see the impact, helping you find ways to improve outcomes. Use this section to see how adjustments may help optimize results.
How Much Data is Required to Run RCA Effectively?
While the short answer is "as much as possible," there is an optimal volume that returns the most concise and efficient results. This volume depends on the number of signals being analyzed, how clearly your target results (pass/fail) are labeled, and how complex the relationship is between the signals and the failure.
The starting point is as follows:
- Parts = # of signals (variable signals the user includes in the model) × 10
- The dataset should include at least 30 parts of each targeted outcome (pass and fail) for best results.
One common challenge with this calculation is the quality of the targeted dataset labels. To be most effective, RCA needs to target unique failure values that describe unique failure modes. For example, if you are targeting a press station, you could target a global result signal (pass/fail), where all failures are treated the same, or you could target a specific failure mode value, such as insertion force, max force, insertion depth, or area under the curve. In the second case, the model can explain the contributors to only a specific output (e.g., insertion depth) and ignore parts with unrelated failures, making the output significantly more accurate.
Using the RCA Module
To configure an RCA analysis path
The Create Analysis Path button appears on the RCA index page in one of two locations:
- No valid RCA analysis paths: A green button appears in the center of the page.
- At least one RCA analysis path: The button appears next to the line selection dropdown.
From the Navigation menu, click .
LinePulse displays the RCA index page.
Select the line you want to configure.
Click
Create Analysis Path.LinePulse opens the creation wizard for the selected line in System Settings.
Complete the RCA analysis path creation steps in System Settings.
To view an existing RCA run's Details and Results
To view results directly from the table, click the timestamp in the Time column.
From the Navigation menu, click .
LinePulse displays the Root Cause Analysis module.
Locate the run and click
in its row.Click View Report Details.
Click View Results
.LinePulse displays results in a new browser tab.
To delete an RCA run
To delete a single run, click
and select Delete Report.To delete multiple runs, select the runs by checking the boxes on the left.
Click
at the top right.
To select all runs, check the box in the first row.
To edit an RCA run
View the results of the run you wish to edit.
Click
REFINEat the top right.
To Create an RCA Run
There are two types of RCAs you can create: Investigate and Optimize.
To create a new Investigate run
- Select Path
- Filters
- Select Target
- Configure Target Continuous or Categorical
- Feature Review
- Configure Report
Step 1: Select Path
From the Navigation menu, click .
LinePulse displays the Root Cause Analysis module.
Click
CREATE NEW.If the current plant contains no RCA-configured lines, the CREATE NEW button is disabled.
Select Investigate.
LinePulse displays the Root Cause Query Builder screen.
(Optional) Select a Line.
Select an Analysis Path.
Click
NEXT.LinePulse displays the next step: Apply Filters.
Proceed to the task Step 2: Filters .
What is an Analysis Path?
Analysis paths define which lines and stations will be analyzed in root cause analysis. There are three parts to the analysis path: target station(s), line, and feeder line(s).
Analysis Paths are configured in collaboration with the Acerta Customer Success team. They will work with your admins to define Target Stations and Feeder Lines. For more information, please contact your Acerta Customer Success team using the Acerta LinePulse Support page.
To create or delete a path, see Root Cause Analysis settings.
The target station is the station where the failure mode being analyzed occurs. For example, many customers select their end-of-line functional tester as the target station, since multiple performance characteristics are verified before the part leaves the line. This allows analysis of broad outcomes such as overall pass/fail, as well as more specific failure modes, such as a “peak torque result.”
Each analysis path supports one target station. The only exception is when parallel stations exist; in these cases, results from the parallel stations can be grouped together for analysis.
The line refers to the production line where the target station(s) are located.
Feeder lines connect data from subassembly lines that supply parts to the target line. To configure feeder lines, the Part ID or Serial Number must remain consistent across both the feeder and target lines. An analysis path can include one or multiple feeder lines.
Step 2: Filters
Complete Step 1 .
Select either Time Based or Part Based.
Select or enter the Period.
(Optional) Select individual Model Numbers.
(Optional) Click
EXCLUDE PARTSto exclude specific Part Numbers.(Optional) Click
REMOVE OUTLIERSand set bounds for the selected signal.(Optional) Click
+ ADD ATTRIBUTES FILTERto include specific Part Attributes.Click
NEXT.LinePulse displays the next step: Select Target.
Proceed to the task Step 3: Select Target .
Step 3: Select Target
Complete Step 2.
See Filters for more information.
(Optional) Enter a search term.
As you type, the signal treeview updates to reflect only those values that match your search terms.
Select a signal from the treeview.
LinePulse enables the
NEXTbutton.(As required) Select additional signals from the treeview.
Click
NEXT.LinePulse displays the next step: Configure Target.
If you have selected a categorical signal, proceed to the task Step 4: Configure Target (categorical signal) .
If you have selected a continuous signal, proceed to the task Step 4: Configure Target (continuous signal) .
You do not have to type the entire signal name. By entering a search term that includes any portion of the desired signal, you instruct LinePulse to display only those signals that contain the term in the signal treeview, making it easier for you to select a specific signal in the next step.
While multiple signals can be selected for the same line, only one signal can be selected per station.
Step 4: Configure Target (categorical signal)
If you selected a continuous signal in the previous step, go to Step 4: Configure Target (continuous signal) .
Complete Step 3 .
Drag any Unassigned Signal Values into one of the target groups.
Click
NEXT.LinePulse displays the next step: Feature Review.
Proceed to the task Step 5: Feature Review .
Target Pass Values represent ideal behavior for analysis, while Target Failure Values represent the behavior you wish to understand. LinePulse ignores any unassigned signal values. You must have at least one Pass and one Fail value.
Step 4: Configure Target (continuous signal)
If you selected a categorical signal in the previous step, go to Step 4: Configure Target (categorical signal) .
Complete Step 3 .
Click and drag on the chart to select a region for analysis.
LinePulse adds a new rule to the Category Builder.
For the newly created rule, select a Type.
Options are Pass or Fail.
(Optional) Manually adjust the region's limits by entering a value in the Upper limit or Lower limit fields.
(Optional) Select
Expand boundaryto extend an Upper or Lower limit to infinity.LinePulse replaces the limit value with the ∞ symbol.
Click
.LinePulse saves the rule.
Click
NEXT.LinePulse displays the next step: Feature Review.
Proceed to the task Investigate run—Step 5: Feature Review .
You can also click ADD RULE to add a new rule.
The distribution graph is capped at 100,000 records. If your selected period exceeds this limit, only the most recent 100,000 data points. This limit only affects measurement-type signals.
Step 5: Feature Review
Complete Step 4.
See either Configure Target (categorical signal) or Configure Target (continuous signal) for more information.
(Optional) Select or deselect
Include Target Stations.(Optional) Select or deselect
Show Downstream Stations.(Optional) Select or deselect signals, as required.
Click
NEXT.LinePulse displays the next step: Configure Report.
Use the search box, SELECT ALL, DESELECT ALL, and CLEAR SELECTION tools to quickly select the desired signals.
Step 6: Configure Report
Complete Step 5.
(Optional) Enter an RCA Run Name.
(Optional) Select an RCA Model Type.
The model type determines the logic used to analyze your data for root causes.
(Optional) Enter Notes.
Click
RUN ANALYSIS.A dialog box appears.
Click
OK.LinePulse displays the RCA main screen and adds the new run to the Historic Runs table.
Insufficient correlation between target and contributing signals” means that signals selected(or left) are not statistically significant to the target signals. Hence, no meaningful analysis is possible. Therefore, add more signals to the list of contributing features or adjust time/part attribute filters. Similar Historical Issues in RCA are pulled from historical runs on the same target line. They are ranked based on proximity of contributing signals of existing run to historical ones. Target signal is also taken into consideration. If no results are pulled back this means that either no runs exist or no sufficient similarity in contributing features is found.
Percent score in contributing features just shows the relative importance of this features among the top selected. The bigger the difference between the two sensors is, the more different their impact is. However, that’s is still the list of most important features from all those being passed to the model.
LinePulse immediately starts the analysis. Depending on your query, results may take several minutes to appear.
LinePulse suggests a default name, but you can override it at any time. Click DEFAULT to restore the suggested name.

To create a new Optimize run
Instead of creating an Optimize RCA run from scratch using the steps above, you can create one directly from an existing Investigate RCA by clicking:
and then + Create Optimize Report
Step 1: Configure Target
From the Navigation menu, click .
LinePulse displays the Root Cause Analysis module.
Click
CREATE NEW.If the current plant contains no RCA-configured lines, the CREATE NEW button is disabled.
Select Optimize.
LinePulse opens the Root Cause Query Builder.
Select a Line.
Select an Analysis Path.
(Optional) Enter a search term.
As you type, the signal treeview updates to reflect matching signals.
Select a signal from the treeview.
LinePulse enables the
NEXTbutton.(As required) Select additional signals from the treeview.
Click
NEXT.LinePulse displays the next step: Select Contributing Signals
What is an Analysis Path?
Analysis paths define which lines and stations will be analyzed in root cause analysis. There are three parts to the analysis path: target station(s), line, and feeder line(s).
Analysis Paths are configured in collaboration with the Acerta Customer Success team. They will work with your admins to define Target Stations and Feeder Lines. For more information, please contact your Acerta Customer Success team using the Acerta LinePulse Support page.
To create or delete a path, see Root Cause Analysis settings.
The target station is the station where the failure mode being analyzed occurs. For example, many customers select their end-of-line functional tester as the target station, since multiple performance characteristics are verified before the part leaves the line. This allows analysis of broad outcomes such as overall pass/fail, as well as more specific failure modes, such as a “peak torque result.”
Each analysis path supports one target station. The only exception is when parallel stations exist; in these cases, results from the parallel stations can be grouped together for analysis.
The line refers to the production line where the target station(s) are located.
Feeder lines connect data from subassembly lines that supply parts to the target line. To configure feeder lines, the Part ID or Serial Number must remain consistent across both the feeder and target lines. An analysis path can include one or multiple feeder lines.
By entering a partial signal name in the search box, you can quickly filter the treeview to find a specific signal.
While multiple signals can be selected for the same line, only one signal can be selected per station.
Step 2: Select Contributing Signals
Complete Step 1.
(Optional) Select or deselect
Include All Stations in Line.(Optional) Select or deselect signals, as required.
Click
NEXT.LinePulse displays the next step: Filters.
Use the search box, SELECT ALL, DESELECT ALL, and CLEAR SELECTION tools to quickly select the desired signals.
Step 3: Filters
Complete Step 2.
Select either Time Based or Part Based.
Enter the Period.
(Optional) Select individual Model Numbers.
(Optional) Click
EXCLUDE PARTSto exclude specific Part Numbers.(Optional) Click
REMOVE OUTLIERSand set bounds for the selected signal.(Optional) Click
+ ADD ATTRIBUTES FILTERto include specific Part Attributes.Click
NEXT.LinePulse displays the next step: Analysis.
Step 4: Analysis
Complete Step 3.
(Optional) Enter an RCA Run Name.
(As required) Enter Notes.
Click
RUN ANALYSIS.A dialog box appears.
Click
OK.LinePulse displays the RCA main screen and adds the new run to the Historic Runs table.
LinePulse immediately starts the analysis. Depending on your query, results may take several minutes to appear.
LinePulse suggests a default name, but you can override it at any time. Click DEFAULT to restore the suggested name.

To Understand the RCA Report
Understanding the Investigate RCA
Working with Investigate RCA Reports
Click
AI-Generated Summaryfor high-level insights and data explanations.Review the Contributing Features list, which ranks signals by their probability of impact.
See the Build Chart for the paths individual parts take through each contributing signal.
Click a feature to view it in the graphs.
Go to Report Parameters → Removed Features to view data excluded from the analysis.
Click
Find Similar Reportsto see previous RCAs.
Understanding the Optimize RCA
Understanding Signal Impacts
The Signal Impacts section is the core of the Optimize RCA report. It contains a chart and a Feature Bins table that together show you how each signal influences the predicted outcome across its range of values.
Bins
Each signal’s values are sorted independently from lowest to highest and divided into 10 percentile-based bins (0–9). Each bin contains approximately 10% of the observations used in the analysis. Bin 0 contains the lowest values, and Bin 9 contains the highest.
Bins contain approximately equal numbers of observations, but their numerical ranges can differ. Values clustered together produce narrower bins, while values spread farther apart produce wider bins.
The Feature Bins table lists these ranges for each signal. A shared bin number represents the same relative position within each signal’s distribution; it does not necessarily contain the same parts across signals.
The Signal Impacts Chart
The chart plots Impact on the Y-axis against Bin on the X-axis for each signal:
- A value of 0 means the signal has no impact on the outcome at that bin.
- Positive values (above 0) indicate the signal is pushing the outcome higher.
- Negative values (below 0) indicate the signal is pushing the outcome lower.
- The shaded area around each line shows the confidence interval. A wider band means more uncertainty at that point.
- Each colored line represents a different signal. Click a signal in the legend to select or deselect it.
The chart is available in three views, which you can cycle through using the arrow buttons at the top right of the section:
- Impact of signals: Shows how much each signal is influencing the predicted outcome across its value range.
- Impact of signals – local coefficient: Shows how sensitive the prediction is to each signal at each bin — useful for identifying where small changes in a signal have the biggest effect.
- Impact of signals – local coefficient (normalized): The same as above, but scaled so all signals can be directly compared against each other.
Use the Feature Bins table to look up the actual value range for a given bin. This helps you understand what real-world signal values correspond to the impacts shown in the chart.
To use Signal Impacts Analysis
The Signal Impacts Analysis panel lets you adjust the value of individual signals and see in real time how those changes affect the predicted outcome.
Click
Signal Impacts Analysis.LinePulse opens the signal adjustment panel, listing each signal with a slider.
Use the Feature Bins table to identify the bin range you want to test for a signal.
Drag the slider for that signal to the desired bin.
The Signal Impacts chart updates to reflect the new predicted outcome based on your adjustment.
(As required) Adjust additional signals using their sliders.
Each change is reflected immediately in the chart, allowing you to see the combined effect of multiple signal adjustments.
Review the chart to evaluate whether your adjustments move the outcome in the desired direction.
To export study data as CSV
CSV export is available for both Investigate and Optimize RCA reports. Export the results table as a CSV file to perform additional statistical analysis outside LinePulse. The export preserves the available result fields, including part details, timestamps, pass/fail results, the target signal, contributing signal values, and path information.
View the results of the RCA run you want to export.
Click
study datato view the results table.Click
exportto export the results table.LinePulse downloads the study data as a CSV file.
Open the CSV file in a spreadsheet or statistical analysis tool.
The exported study data includes the following fields:
| Column | Data included |
|---|---|
partId | Part identifier. |
timestamp_first | Earliest measurement timestamp included in the part's cumulative path. |
timestamp_last | Latest measurement timestamp included in the part's cumulative path. |
runNumber | Number identifying a successive attempt by the same part to reach the configured target station. |
model number | Part model number. |
pass/fail | Pass or fail result type. |
| Contributing signals (20 columns) | Values for the 20 contributing signals, with each column headed by the actual signal name. |
| Target signal | Target signal of this RCA run. |
path | Comma-separated sequence of stations recorded for the part, ordered by time, up to that attempt's target visit. |
For runNumber, consecutive measurements at the target station count as one visit; the last measurement marks that visit. The current implementation retains the latest 35 visits for each part and numbers those visits starting at 1.
In path, each station is formatted as <line_seq>_<stationName>. Repeated stations remain in the sequence.
Why Does an RCA Run Fail and How Can You Fix It?
An RCA run may fail for different reasons. The most common ones are:
Not enough samples (parts)
RCA needs enough parts to detect meaningful patterns. If the filtered dataset is too small, the run will fail.
Solution
- Adjust the filtering conditions to include more samples.
No valid signals
Although you may select several signals, they could all be trivial, such as constant values or signals with missing values.
Solution
- Please include more signals.
Pass or fail outcomes are too rare
For a successful run, include at least 10 parts for each targeted outcome (pass and fail).
Solution
- Include more samples so both outcomes are sufficiently represented.
Target not configured properly
Solution
- Reconfigurate the target following the instructions.