About Quality Monitors​

The Quality Monitor module allows you to monitor KPIs in real time and gain insights into future behavior. A quality monitor is a predictive tool trained on historical performance to monitor key performance indicators(KPIs) in real time. When a quality monitor is deployed, you are automatically alerted when the selected KPI is predicted to trend in the wrong direction based on current and past behavior. The machine learning algorithm then automatically assesses the contributing signals to inform you of the likely issue(s).

How do Quality Monitors Work​

Quality monitor best practices consist of the following three steps:

  1. Configuring monitors
  2. Real-time monitoring and retraining
  3. Reviewing monitor reports

Quality monitors are configured by selecting a KPI to monitor (such as failure rate), along with a set of contributing signals that directly influence the KPI. Once a monitor has been configured and deployed into production, LinePulse continuously assesses the KPI in real time as results come in. As data is analyzed, it also continuously trains the monitor, which predicts and identifies performance issues by comparing historical performance to the current state of the KPI in relation to the monitor's selected contributing signals. When diminishing performance is detected, the quality monitor triggers an alert and produces a report that details the signal or signals adversely affecting the KPI.

A quality monitor alert is based on both the current failure rate and how the failure rate is changing. LinePulse first calculates failure rate over the configured part-count window. It then evaluates the recent average change in failure rate over the observation window and compares that change with historical changes using the monitor’s quantile settings. An alert is triggered only when the latest failure rate meets the configured minimum alert threshold and the recent failure-rate increase is positive and unusually high compared with historical behavior.

The report generated by an alert details the changing KPI metric, along with the signal or signals adversely affecting the KPI. Based on this report, you can either take direct corrective actions on the line or investigate the issue further using the RCA or Capability Metrics modules.

tip

Automatically send alerts generated by quality monitors to Microsoft Teams. See MS Teams Integration for more information.

Understanding Quality Monitors​

Quality Monitor Example

Target Failure Rate​

The main chart shows failure rate over records or time.

  • Use Records to understand failure rate by part count.
  • Use Time to identify shifts, downtime, or changeovers that may explain changes in failure rate.

Group results by part attributes to see whether specific models are driving failures.

Contributing signal analysis​

When a Quality Monitor triggers, LinePulse identifies the signals that contributed most to the failure rate change. Each signal includes three plots:

  • Plot 1: Actual vs Expected
    Compares recent signal values to expected behavior to identify drift.

  • Plot 2: Historic vs Declining Distribution
    Shows how the signal’s distribution has shifted during the failure period.

  • Plot 3: Pass vs Fail Histogram

Using the Quality Monitors Module​

Viewing Quality Monitors Demonstration

To activate or deactivate a quality monitor​

  1. From the Navigation menu, click Quality Monitors.

    LinePulse displays the Quality Monitors module.

  2. Enable or disable the Active column for the selected monitor.

To view a quality monitor alert report​

  1. From the Navigation menu, click Quality Monitors.

    LinePulse displays the Quality Monitors module.

  2. Click the desired monitor's Latest Alert value.

    LinePulse displays an alert report for the selected monitor.

  3. Review the Monitor Parameters section to see the monitor configuration, including the Warning Threshold and Critical Threshold values.

    These values are shown on the report page even if Auto Calculate Thresholds was enabled, so you can see which thresholds applied when the quality monitor alerted.

    These thresholds help determine whether the current failure rate is high enough to be considered for alerting. However, the breach decision also depends on the recent rate of increase in failure rate, so crossing a threshold alone does not necessarily trigger an alert.

tip

See Working with Charts and Working with Tables to learn how to navigate and interact with the monitor report.

Creating a Quality Monitor​

To create a new Quality Monitor: Step 1: Select Target​

  1. From the Navigation menu, click Quality Monitors.

    LinePulse displays the Quality Monitors module.

  2. Click CREATE NEW.

    The Quality Monitor Builder appears.

  3. (Optional) Select a Line.

  4. (Optional) Enter a search term.

    As you type, the signal treeview updates to reflect only those values that match your search terms.

  5. tip

    You do not have to type the entire signal name. By entering a search term that includes any portion of the desired signal, you instruct LinePulse to display only those signals that contain the term in the signal treeview, making it easier for you to select a specific signal in the next step.

  6. Select a signal from the treeview.

    LinePulse enables the NEXT button.

    note

    Only one signal can be selected.

  7. Click NEXT.

    LinePulse displays the next step: Configure Target.

To create a new Quality Monitor: Step 2: Configure Target​

  1. Complete Step 1 .

  2. (As required) Drag items from the Ignore Signal Values list into one of the target groups.

    note

    Target Pass Values represent those signal values that exhibit ideal behavior for analysis, while Target Failure Values represent the signal values you wish to understand. LinePulse ignores any unassigned signal values.

  3. Click NEXT.

    LinePulse displays the next step: Select Signals.

To create a new Quality Monitor: Step 3: Select Signals​

  1. Complete Step 2 .

  2. (Optional) Enter a search term.

    As you type, the signal treeview updates to reflect only those values that match your search terms.

  3. tip

    You do not have to type the entire signal name. By entering a search term that includes any portion of the desired signal, you instruct LinePulse to display only those signals that contain the term in the signal treeview, making it easier for you to select a specific signal in the next step.

  4. Select or deselect signals, as required.

    note

    A minimum of 3 and a maximum of 20 signals must be selected.

  5. Click NEXT.

    LinePulse displays the next step: Filters.

To create a new Quality Monitor: Step 4: Apply Filters​

  1. Complete Step 3 .

  2. Enter or select a Period.

  3. (Optional) Select individual Model Numbers.

  4. (Optional) Select an Operation Count value.

  5. (Optional) Enter any parts you wish to exclude under Excluded Parts.

    Separate each excluded part serial number with a comma.

  6. (Optional) Click + ADD ATTRIBUTES FILTER to include specific Part Attributes.

  7. Click NEXT.

    LinePulse displays the next step: Configure Alerts.

To create a new Quality Monitor: Step 5: Configure Alerts​

  1. Complete Step 4 .

  2. (Optional) If you want LinePulse to calculate the thresholds for you, select Auto Calculate Thresholds.

    If Auto Calculate Thresholds is enabled, ignore the next two steps.

  3. (Optional) Enter a Warning Threshold percentage.

  4. (Optional) Enter a Critical Threshold percentage.

  5. Click NEXT.

    LinePulse displays the next step: Configure Monitor.

To create a new Quality Monitor: Step 6: Configure Monitor​

  1. Complete Step 5 .

  2. Enter a Quality Monitor Name.

    This field is mandatory. Try to make it as descriptive as possible.

  3. (As required) Enter Quality Monitor Notes.

  4. Click DEPLOY MONITOR.

    LinePulse displays the Quality Monitors main screen and adds your newly created monitor to the list.

Quality monitors look back at the data 20 times more than the selected monitor count of up to 60000 parts produced and computes the thresholds. The exact values for different thresholds/levels are not being displayed currently. Nor are they updated dynamically later. Recreating the same monitor later or setting those thresholds manually after usage is one way to change the threshold values. Default monitor threshold values are 5% for medium and 10% for high.

Only Result signals can be configured as a Quality Monitor target. That is why you only see Result signals in the selection panel at Step 1: Select Target. If you want to use a Measurement signal as the target for a Quality Monitor, you need to change its entity type to Result first:

  1. Go to Settings
  2. Open Signal Management
  3. Select the signal
  4. Use the Entity Type dropdown
  5. Change it from Measurement to Result After the signal is configured as a Result signal, it should be available in the Quality Monitor Step 1 selection panel. When the quality monitor triggers an alert, it will produce a report